DMS flow measurement systems
The Raziol flow measurement systems allow the online monitoring, control and recording of the consumption of forming lubricants applied to blanks, moulded parts, coils etc. Depending on the application, flow measurement systems with a resolution of 100 impulses per litre up to 25,000 impulses per litre are used.
Operation is self-sustaining or is integrated within a roller lubricator or spray system concept. All flow measurement systems are calibrated in correlation with the respective requirements of the customer, the desired measuring range and the chemical / physical properties before they are dispatched from the factory. Furthermore, Raziol provides yearly maintenance of the equipment and recalibration as required. Raziol flow measurement systems are also extremely advantageous within the context of your quality control.
Self-sustaining systems
- Flow rates and total consumption can be ascertained and displayed, for example in CSV format
- Limit values (min. and max.) based on the actual consumption of the system can be entered and stored in accordance with the respective product
- Emission of a warning or fault signal in the event of excessive or insufficient quantities to facilitate assessment by the customer
Use in roller lubricators
- Monitoring of the preset flow volume in the feeding system to the lubrication rollers
- A warning or fault signal is emitted if the actual value falls below or exceeds the preset quantity, for the evaluation by the superordinate control system
Use in spraying systems
- Product-dependent saving of desired application volume [g/m²] in the respective lubrication pattern for Premium spray systems
- The Raziol control system SPC 4000B checks, in interaction with the measuring head, the amount supplied to the nozzles and readjusts this amount fully-automatically, if required
- The recording takes place in the operation log
- Automatic calibration checks for the nozzles incl. evaluation in the control and system concept have been integrated